Researchers at the University of East Anglia in collaboration with Hoya Surgical Optics have improved a laboratory model that simulates cataract surgery on human donor eyes.
Their latest human model allows evaluation of artificial intraocular lens (IOL) implants under conditions that better reflect the post-surgical environment.
A cataract is a clouding of the eye’s lens and affects millions worldwide. At present, the only way of treating cataract is with surgery and it is estimated that by 2020, more than 30 million such operations will be performed annually.
During cataract surgery, the eye’s cloudy natural lens is removed and replaced with an IOL.
Initially, outcomes from cataract surgery are superb, but a haziness known as Posterior Capsule Opacification (PCO) can develop in a significant number of patients following surgery.
At the moment the only treatment for PCO is laser surgery - which is expensive and not without risks. There is therefore a need for better understanding the physiological events driving PCO and to better manage the condition.
The human capsular bag model was pioneered at UEA in the 1990s and has progressively evolved with time.
Lead researcher Prof Michael Wormstone, from UEA’s School of Biological Sciences, said: “Our model now mimics the transient nature of inflammation that patients experience after cataract surgery. It is more reflective of clinical events and allows comparative evaluation of different types of IOLs.
“We believe this latest model will allow assessment of current commercial IOLs and will aid the development of next generation lenses.”
The team used this clinically relevant model to assess the influence of two commercial market-leading IOLs (Alcon AcrysofTM and Hoya VivinexTM) on PCO management.
Their findings showed that cell growth on the posterior capsule was reduced, light-scatter in the central visual axis was found to be lower and growth on the IOL surface was significantly reduced with the Hoya VivinexTM IOL relative to the Alcon AcrysofTM.
The research team conclude that “our model system predicts that the Hoya VivinexTM is better able to manage events leading to PCO than the Alcon AcrysofTM IOL”.
The research was funded by Hoya Surgical Optics and The Humane Research Trust.
‘An in vitro human lens capsular bag model adopting a graded culture regime to assess putative impact of IOLs on PCO formation’ is published in the journal Investigative Ophthalmology and Visual Science on January 10, 2019.
Researchers at the University of East Anglia (UEA) are launching a ground-breaking project to improve the lives of people affected by smell disorders.
Read moreNurses around the world use intuition to work out how sick a patient is before triaging for treatment according to new research from the University of East Anglia.
Read moreA new study published today shows the number of sexual partners we have changes as we age and there are some surprising results.
Read more